xFeatures Adjustable temperatures: from 35º C to 200º C. Temperature homogeneity:± 4º C Temperature stability:± 1º C Temperature display accuracy:± 2º C Maximum admissible vacuum: 0,01 mbar. Safety according to: EN-61010-1, EN-61010-2-010. Double safety glass against implosions according to regulations Safety thermostat: class 2 incorporated from factory. Time and temperature controller: digital by microprocessor. Temperature probe: Pt 100 Class A Epoxy resin oven painted external case. Interior made in polished stainless steel AISI 304.
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
Autoclave (Sterilizer) An autoclave is a strong heated container used for chemical reactions and other processes in need of high amounts of pressure and temperature. Sterilization Autoclaves have a variety of uses in the fields of microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, prosthetics fabrications, etc.
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
-External size (WxDxH) 1100x750x2200 mm -Internal size (WxDxH) 940x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
Features Natural air convection. Adjustable temperature from room temperature +5º C to 80º C. Temperature regulation by microprocessor Delay & incubation time programmable between 0 and 99h Homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device. Connection to PC (USB) Control software (optional) Environment: 0 to 50ºC, max RH 85%
-External size (WxDxH)1300x750x2250 mm -Internal size (WxDxH) 1150x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
Max 130°C Vertical Autoclave 100L. Material External : Steel Plate with Powder Heating Coated Dimension External (W×D×H ) : 550x680x1070mm 650x780x1150 mm
CO2 Incubators The SHEL LAB CO2 Incubator family includes the following design features and the longest warranty period on the market – a five year limited warranty on most models: Infrared (IR) CO2 Sensor is extremely quick to recover CO2 levels after door openings and ensures superior pH stability Unique air jacket design provides excellent temperature uniformity of +/-0.25°C at 37°C Humidity levels, maintained through evaporation, of up to 95% Data logging capabilties
Co-using Angle & Swing rotor, Ergonomically arranged and designed, RPM/RCF auto calculating, Changing term of timer during operation, memory for saving experiment condition, Fast Cooling, AC induction Motor Cooling System, Lid latch by motor preventing imbalance of sample.
Features Forced air convection. Adjustable temperature from room temperature + 5º C to 250º C. Temperature regulation by microprocessor. Delay & incubation time programmable between 0 and 99h Temperature homogeneity and stability according to DIN-12880. Safety according to EN-61010-1, EN-61010-2-010. Heating by electric resistance, assembled in independent chamber, allowing an optimal stabilization of temperature. External case epoxy resin painted. Inner chamber, inner side door and trays made in stainless steel AISI 304. Silicone sealing gasket. Adjustable aeration device.
Pathological sampling bench is widely used in hospital pathology department, pathology laboratory, etc. Reasonable ventilation system protects operator away from the harmful gas produced by the formalin during sampling. The hot & cold water system ensures it can adapt work in different climates.
AHS-DRY Raypa autoclaves Intended use: Suitable to sterilize: wrapped or unwrapped solids, small porous elements and hollow elements type B (slightly deep and broad cavities). glass, plastic, metallic elements, waste bags. Features: Chamber, lid and closure made of AISI-304 stainless steel Total control by microprocessor: Ten sterilization programs. Six programs are user free. 7 Litres feeding water reservoir. Automatic water filling. Automatic drying Includes RS-232 port to connect to a printer/PC. Safety: Safety valve and thermostat. Door hydraulic blocking system. Open lid sensor
Biological Safety Cabinet (class II, A2) Three protection: operator, sample and environment. Airflow system: 70% air re-circulation, 30% air exhaust. Suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
เป็นตู้ที่ใช้ทำความสะอาดร่างกายด้วยการเป่าลม สามารถช่วยกรองฝุ่นละอองหรือสิ่งสกปรกต่างๆก่อนเข้าไปในห้องปฏิบัติการแบบ Clean room ได้ ใช้ระบบกรองแบบ HEPA Filter ซึ่งสามารถกรองอนุภาคขนาด 0.3 ไมครอน ได้อย่างน้อย 99.999% มีระดับความสะอาด Class 100
-External size (WxDxH) 1500x760x2200 mm -Internal size (WxDxH) 1350x600x650 mm -Moterized front window. -Two layers laminated toughened glass >5mm, anti UV. -Time reserve function. -Interlock funtion. -Microprocessor control system. -HEPA filter life and UV life indicator. -0% air re-circulation, 100% air exhaust. -Automatic air speed adjustable with filter block. -Most accessories are standard. No need to pay more, save your money. -Work area surrounded by negative pressure, it can ensure maximum safety in work area. -Visual&Audio alarm when filter replacement, window over height, abnormal air flow velocity. -PVC exhaust duct, diameter 300 mm.
GeneMax is a PCR device to the new generation of the company. Since the company was founded 10 years of technology and performance of the peak of maximum feedback, is also 10 years to support our customers.
GeneMax adheres to FERROTEC's Peltier research and development, manufacture and application abili1y. Its performance and function has reached a new level, which can realize the perfect optimization for the annealing temperature. GeneMax is with l 0.4 inches large LCD touch screen, more convection for the man-machine interaction. It's efficient and stable by using ARM9 processor and ThreadX system. Moreover, GeneMax is launched with a gold-plated block at the first time. Its performance is more superior in temperaturecontrol. At the same time, Bluetooth signal converter can ealize wireless link between the instrument and computer.